Show simple item record

dc.contributor.authorCamargo, Patrícia Faria
dc.contributor.authorDi Thommazo-Luporini, Luciana
dc.contributor.authorCarvalho Junior, Luiz Carlos Soares de
dc.contributor.authorGoulart, Cássia da Luz
dc.contributor.authorSebold, Rayane
dc.contributor.authorSantos, Polliana Batista dos
dc.contributor.authorRoscani, Meliza Goi
dc.contributor.authorSilva, Audrey Borghi
dc.date.accessioned2022-02-09T10:05:56Z
dc.date.available2022-02-09T10:05:56Z
dc.date.issued2020-08-12
dc.identifierhttps://doi.org/10.2147/copd.s260284por
dc.identifier.citationCAMARGO, Patrícia Faria; DI THOMMAZO-LUPORINI, Luciana; CARVALHO JUNIOR, Luiz Carlos Soares de; GOULART, Cássia da Luz; SEBOLD, Rayane; SANTOS, Polliana Batista dos; ROSCANI, Meliza Goi; SILVA, Audrey Borghi. Association between the predictors of functional capacity and heart rate off-kinetics in patients with Chronic Obstructive Pulmonary Disease. Repositório Institucional da UFSCar, 2020. Dataset. Disponível em: https://repositorio.ufscar.br/handle/ufscar/15568.*
dc.identifier.urihttps://repositorio.ufscar.br/handle/ufscar/15568
dc.descriptionBackground: The heart rate (HR) kinetics as well as other predictors of functional capacity such as the Chronic Obstructive Pulmonary Disease (COPD) Assessment Test (CAT), the Duke Activity Status Index (DASI) and the handgrip strength (HGS) represent important tools in assessing the impact of COPD on exercise performance and health status of individuals with COPD. Purpose: To verify the relationship between functional capacity, measured using the six-minute walking test (6MWT), with the HR off-kinetics, HGS and the DASI and CAT scores. Methods: For this cross-sectional study, 29 subjects with COPD underwent body composition, pulmonary function and cardiac function tests. Subsequently, the DASI and CAT questionnaires and HGS test were performed. The beat-to-beat R-R intervals (IRR) were collected in rest, during the test and in recovery after the 6MWT. The HR off-kinetics was obtained during a 360-second period in post-exercise recovery through the HR mono-exponential decay. Results: Moderate correlations were observed between: 1) walked distance (WD) in the 6MWT and the CAT and DASI scores (r= −0.58, p=0.001 and r= 0.58, p=0.001, respectively); 2) WD and HGS (r=0.37, p=0.05); 3) and WD and HR off-kinetics (τ; r= −0.54, p=0.002 and MRT; r= −0.55, p=0.002, respectively). Conclusion: The 6MWT performance is a direct measurement to evaluate functional capacity. Additionally, it is related to other direct and indirect markers for functional evaluation in patients with COPD. These results suggest the application of these tools in clinical practice, based on the accessibility, non-invasive character and easy applicability of these methods.eng
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)por
dc.language.isoengeng
dc.publisherUniversidade Federal de São Carlospor
dc.relation.urihttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7438181/#:~:text=The%206MWT%20performance%20is%20directly,kinetics%20in%20individuals%20with%20COPD.por
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Brazil*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/br/*
dc.subjectCOPDeng
dc.subjectExerciseeng
dc.subjectQuestionnaireseng
dc.subjectKineticseng
dc.titleAssociation between the predictors of functional capacity and heart rate off-kinetics in patients with Chronic Obstructive Pulmonary Diseaseeng
dc.typeDataseteng
dc.publisher.initialsUFSCarpor
dc.publisher.programPrograma de Pós-Graduação em Fisioterapia - PPGFtpor
dc.subject.cnpqCIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONALpor
dc.description.sponsorshipIdProcesso nº 2015/26501–1, Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)por
dc.description.sponsorshipIdProcesso nº 2018/00860-3, Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)por
dc.publisher.addressCâmpus São Carlospor
dc.contributor.authorlatteshttp://lattes.cnpq.br/8975177658472167por
dc.contributor.authorlatteshttp://lattes.cnpq.br/3990285037066747por
dc.contributor.authorlatteshttp://lattes.cnpq.br/7342560022121661por
dc.contributor.authorlatteshttp://lattes.cnpq.br/9790656360225486por
dc.contributor.authorlatteshttp://lattes.cnpq.br/6250635737922582por
dc.contributor.authorlatteshttp://lattes.cnpq.br/9224940191005426por
dc.contributor.authorlatteshttp://lattes.cnpq.br/1298051150234135por
dc.contributor.authorlatteshttp://lattes.cnpq.br/4855616925791895por
dc.identifier.urlhttps://repositorio.ufscar.br/handle/ufscar/14243por
dc.publisher.departmentDepartamento de Fisioterapia - DFisiopor


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Brazil
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Brazil