Monitoramento em tempo real da orientação molecular de poliestireno e em misturas com polimetilmetacrilato durante a extrusão
(Universidade Federal de São Carlos, 2011-03-02)
In this work it was studied the flow orientation of pure polystyrene and its diluted mixtures with polymethylmethacrylate as second phase during extrusion process by in-line monitoring of the polarized transmitted light ...
Desenvolvimento de um detector de espalhamento de luz LASER de baixo ângulo LALLS operando em tempo real na extrusão
(Universidade Federal de São Carlos, 2005-12-08)
In the present work a prototype of a low angle laser light scattering was developed and installed in an extruder in order to operate in real time. The equipment was built by the research group of which the author is member, ...