Logo do repositório
Comunidades e Coleções
Todo o repositório
Estatísticas
Sobre
English
العربية
বাংলা
Català
Čeština
Deutsch
Ελληνικά
Español
Suomi
Français
Gàidhlig
ગુજરાતી
हिंदी
Magyar
Italiano
Қазақ
Latviešu
मराठी
Nederlands
Polski
Português
Português do Brasil
Русский
Srpski (lat)
Српски
Svenska
Türkçe
Yкраї́нська
Tiếng Việt
Esqueceu sua senha?
  1. Início
  2. Pesquisar por Data

Navegando por Data de Publicação, começando com "2011-05-19"

Filtrar resultados por ano ou mês
Agora exibindo 1 - 1 de 1
  • Resultados por página
  • Opções de Ordenação
  • Carregando...
    Imagem de Miniatura
    listelement.badge.dso-typeItem,
    Determinação simultânea de íons metálicos por meio de técnicas eletroanalíticas e quimiométricas
    (Universidade Federal de São Carlos, 2011-05-19) Farias, Marco Antonio dos Santos; Souza, Ernesto Chaves Pereira de; https://lattes.cnpq.br/1505400360366643; https://lattes.cnpq.br/2589951282251863
    In this work, the determination of three metallic ions was performed, namely Zn2+, Cd2+ and Pb2+, in very different concentration range, from _g/L until mg/L, using differential pulse anodic stripping voltammetry over Carbon Fiber electrode where a Mercury film was deposited. Initially a factorial design of 23 was built where all possible combination among the ion concentrations were contemplated and in this way all interactions among the metallic ions were measured. The voltammetric curve was mean centered before the chemometric analysis. After that, the data were analysed using Partial Least Squares in the Principal Components domain was the used to quantify the ion concentration. The data treatment has been validated using cross and external validation methods. The final results showed low precision in the validation compared to those methods commonly used in the literature. After the chemometric treatment realized at first group of samples, two more groups in an extended concentration range, were built and tested using the same methodology. In these cases, again, the data validation lead to a low precision for practical application. It is important to emphasize that the low precision in the validation does not mean a chemotric approach to analyse electroanalytical data is not adequate, instead it means that among those chemometric technique, in the dissertation, we chose an inadequate one.
Siga as redes sociais do SIBi
Contato

Repositório Institucional da UFSCar (RI UFSCar)

Av. Biblioteca Comunitária, Campus São Carlos

Rod. Washington Luís, km 235 - SP-310

São Carlos, SP, 13565-905 (16) 3351-8477

Email: repositorio@ufscar.br

Acessos ao repositorio.ufscar.br

DSpace software copyright © 2002-2026 LYRASIS

  • Acessibilidade
  • Política de Privacidade
  • Termos de Uso
  • Enviar uma Sugestão