Logo do repositório
Comunidades e Coleções
Todo o repositório
Estatísticas
Sobre
English
العربية
বাংলা
Català
Čeština
Deutsch
Ελληνικά
Español
Suomi
Français
Gàidhlig
ગુજરાતી
हिंदी
Magyar
Italiano
Қазақ
Latviešu
मराठी
Nederlands
Polski
Português
Português do Brasil
Русский
Srpski (lat)
Српски
Svenska
Türkçe
Yкраї́нська
Tiếng Việt
Esqueceu sua senha?
  1. Início
  2. Pesquisar por Data

Navegando por Data de Publicação, começando com "2012-07-23"

Filtrar resultados por ano ou mês
Agora exibindo 1 - 1 de 1
  • Resultados por página
  • Opções de Ordenação
  • Carregando...
    Imagem de Miniatura
    listelement.badge.dso-typeItem,
    Desenvolvimento de imunossensores piezelétrico e eletroquímico para detecção de amostras de interesse agronômico e de saúde
    (Universidade Federal de São Carlos, 2012-07-23) Afonso, André Santiago; Mattoso, Luiz Henrique Capparelli; https://lattes.cnpq.br/5839043594908917; https://lattes.cnpq.br/0101777160876872
    This work shows development of immunosensors for agronomic interest and public heath. The first was a piezoeletric immunosensor to detect a cysteine peptidase, a potencial biomarker for Xanthomonas citri subsp. citri that cause a citrus Canker. Another was electrochemical immunosensor based on gold nanoparticles as a label and magnetic beads as capture phase of Salmonella enterica subsp. enterica sorovar Typhimurium LT2 (S). The piezoelectric immunoassay was based on immobilization of polyclonal antibody against CPXaC (anti-CPXaC), produced in rabbit, onto three different monolayers that modified gold quartz crystal, which were evaluated by monitoring frequency and energy dissipation in real time when 64.5×10-8 mol L-1 of CPXaC was added. The better relation between analytical response and energy dissipation was obtained with immobilization onto 11- mercaptoundecanoic acid which presented a detection limit of 13.0 nmol L-1 as well as good values for the kinetic and equilibrium binding constant. The immunosensor showed good specificity with no response for different proteins include another cysteine peptidase that is used as a target for detects Xylella fastidiosa bacterium responsible for other important disease in citrus. For detection of Salmonella using a magneto-immunoassay and gold nanoparticles (AuNPs) as label was developed based on the use of a screen-printed carbon electrode (SPCE) that incorporates a permanent magnet underneath. Salmonella spiked in milk samples (i.e. skimmed milk) have been tested by using anti-Salmonella magnetic beads (MBs-SAb) as capture phase and sandwiching afterwards with AuNPs modified antibodies (SAb-AuNPs). AuNPs detection using differential pulse voltammetry (DPV) following a previous established procedure is performed. And a detection limit of 143 CFU mL-1 and a linear range of from 103 to 106 CFU mL-1 of Salmonella, with a coefficient of variation of about 2.4%, was obtained. Recoveries of the sensor by spiking skimmed milk with different quantities of Salmonella of about 83 and 94 % for xviii 1.5 x 103 and 1.5 x 105 CFU mL-1 were obtained, respectively. This work demonstrated the possibility to detect CPXaC with a piezoelectric immunosensor as well as electrochemical immunosensor to detect Salmonella spiked in milk samples.
Siga as redes sociais do SIBi
Contato

Repositório Institucional da UFSCar (RI UFSCar)

Av. Biblioteca Comunitária, Campus São Carlos

Rod. Washington Luís, km 235 - SP-310

São Carlos, SP, 13565-905 (16) 3351-8477

Email: repositorio@ufscar.br

Acessos ao repositorio.ufscar.br

DSpace software copyright © 2002-2026 LYRASIS

  • Acessibilidade
  • Política de Privacidade
  • Termos de Uso
  • Enviar uma Sugestão