Logo do repositório
Comunidades e Coleções
Todo o repositório
Sobre
English
العربية
বাংলা
Català
Čeština
Deutsch
Ελληνικά
Español
Suomi
Français
Gàidhlig
ગુજરાતી
हिंदी
Magyar
Italiano
Қазақ
Latviešu
मराठी
Nederlands
Polski
Português
Português do Brasil
Русский
Srpski (lat)
Српски
Svenska
Türkçe
Yкраї́нська
Tiếng Việt
Esqueceu sua senha?
  1. Início
  2. Pesquisar por Data

Navegando por Data de Publicação, começando com "2005-02-21"

Filtrar resultados por ano ou mês
Agora exibindo 1 - 2 de 2
  • Resultados por página
  • Opções de Ordenação
  • Carregando...
    Imagem de Miniatura
    listelement.badge.dso-typeItem,
    Análise do manejo florestal de "Baixo impacto" e da caça de subsistência sobre uma comunidade de primatas na Floresta Estadual de Antimary (Acre, Brasil)
    (Universidade Federal de São Carlos, 2005-02-21) Calouro, Armanado Muniz; Pires, José Salatiel Rodrigues; https://lattes.cnpq.br/3412204514901170
  • Carregando...
    Imagem de Miniatura
    listelement.badge.dso-typeItem,
    Caracterização das respostas cardiorrespiratórias e eletromiográficas para exercícios de carga constante em intensidades próximas ao limiar de anaerobiose ventilatório
    (Universidade Federal de São Carlos, 2005-02-21) Pithon, Karla Rocha; Silva, Ester da; https://lattes.cnpq.br/0120120410847507
    This research aimed to identify the ventilatory anaerobic threshold (VAT) in a ramp continuous test and to apply mathematical and statistical methods to study the stability of the variables during the exercise performed in discontinuous steps near the VAT intensity. Eight young men (22,75 ± 2,25 years) were submitted to a ramp continuous ergoespirometric test (protocol I), with 20 to 25 W.min-1 power increments, on an electromagnetic braked cycle ergometer and to 3 discontinuous steps (protocol II), each one lasting 15 minutes, with 70% of VAT (step 1), 100% of VAT (step 2) and 130% of VAT (step 3). The metabolic and ventilatory variables ( O2, CO2, E, PetO2, PetCO2) were collected on a breath-by-breath basis, heart rate (HR) was collected on a beat-to-beat basis, and RMS was calculated for the myoelectrical signal of vastus lateralis muscle. In protocol I, VAT was determined by the loss of parallelism between O2 and CO2; in protocol II data a semi-parametric mathematical and statistical model was applied. For statistical analysis the median confidence interval was applied, α= 5% and descriptive analysis. HR was statistically different between VAT and step 3 and among steps 1, 2 and 3. For O2, CO2 and E data the results were similar, with significant statistical differences between VAT and steps 2 and 3 and among the three steps. For PetO2 the statistical difference was observed between VAT and step 3; PetCO2 and RMS did not show statistical differences. The analysis of the 3o to 9o minute (T1) and of the 9o to 15o minute (T2) of the steps, showed for step 1: for HR 7 stables (S) and 1 crescent (C) and O2 and CO2 8S in T1 and T2; PetCO2 7S and 1 decreasing (D) in T1 and 7S and 1C in T2; PetO2 5S and 3C in T1 and 7S and 1D in T2; RMS 4S, 3D and 1C in T1 and 7S and 1D in T2. For step 2: HR 3S and 5C in T1 and 5S and 3C in T2; O2 and CO2 8S in T1 and T2; PetCO2 4S and 4D in T1 and 5S and 3D in T2; PetO2 5S and 3C in T1 and 8S in T2; RMS 4S, 2D and 2C. For step 3: HR 8C in T1 and 5S and 3C in T2, CO2 8S and O2 7S and 1C in T1 and O2 and CO2 8S in T2; PetCO2 1S and 7C in T1 and 5S, 1C and 2D in T2; PetO2 4S and 4C in T1 and 5S, 2D and 1C in T2; RMS 4S, 2D and 2C in T1 and 4S, 3D and 1C in T2. Conclusions: for young volunteers, on a step protocol, it is necessary to decrease the power intensity around 30% to reach similar cardiorrespiratory values of VAT. PetCO2 and HR showed more sensitive responses to power intensities above VAT and can be used as first signaling of exercise above VAT.
Siga as redes sociais do SIBi
Contato

Repositório Institucional da UFSCar (RI UFSCar)

Av. Biblioteca Comunitária, Campus São Carlos

Rod. Washington Luís, km 235 - SP-310

São Carlos, SP, 13565-905 (16) 3351-8477

Email: repositorio@ufscar.br

Acessos ao repositorio.ufscar.br

DSpace software copyright © 2002-2026 LYRASIS

  • Acessibilidade
  • Política de Privacidade
  • Termos de Uso