Logo do repositório
Comunidades e Coleções
Todo o repositório
Sobre
English
العربية
বাংলা
Català
Čeština
Deutsch
Ελληνικά
Español
Suomi
Français
Gàidhlig
ગુજરાતી
हिंदी
Magyar
Italiano
Қазақ
Latviešu
मराठी
Nederlands
Polski
Português
Português do Brasil
Русский
Srpski (lat)
Српски
Svenska
Türkçe
Yкраї́нська
Tiếng Việt
Esqueceu sua senha?
  1. Início
  2. Pesquisar por Data

Navegando por Data de Publicação, começando com "2007-08-03"

Filtrar resultados por ano ou mês
Agora exibindo 1 - 1 de 1
  • Resultados por página
  • Opções de Ordenação
  • Carregando...
    Imagem de Miniatura
    listelement.badge.dso-typeItem,
    Determinação voltamétrica de aspartame e ciclamato de sódio em produtos dietéticos empregando um eletrodo de diamante dopado com boro
    (Universidade Federal de São Carlos, 2007-08-03) Medeiros, Roberta Antigo; Fatibello Filho, Orlando; https://lattes.cnpq.br/9859737944357808; https://lattes.cnpq.br/3760577547828061
    The development of electroanalytical procedures for aspartame and sodium cyclamate determination in dietary products using a boron doped diamond (BDD) electrode and the square wave voltammetry (SWV) is reported in this work. The first procedure development is reported in related to the determination of aspartame in dietary products employing BDD electrode and the SWV technique after optimization of the experimental conditions. The recovery of aspartame from 8 samples ranged from 95.9 % to 104.4 % of the added amount. The analytical curve was linear in the aspartame concentration range from 9.9 x 10-6 mol L-1 to 5.2 x 10-5 mol L-1 with a detection limit of 2.3 x 10-7 mol L-1. The relative standard deviation for 5 successive determinations of 1.0 x 10-4 mol L-1 aspartame was 0.17 % and the relative standard deviation for 5 determinations of aspartame in different days was 2.8 %. The concentration of aspartame determined in several dietary products using the BDD electrode and those concentrations determined using a HPLC method are in close agreement (calculated t-values did not exceed the critical values at the 95 % confidence level) and within an acceptable range of error. In the sequence, the analytical determination of sodium cyclamate was studied by oxidation of this substance on BDD electrode employed the SWV. The analytical curve for sodium cyclamate was linear in the concentration range from 5.0 x 10-5 to 4.1 x 10-4 mol L-1 with a detection limit of 4.8 x 10-6 mol L-1. The relative standard deviation for five successive measurements was 1.1 % and the relative standard deviation for determinations of 3.0 x 10-3 mol L-1 sodium cyclamate in five different days was 2,4 %. The recoveries values from five samples ranged from 98.6 % to 106,0 % and the results found using the proposed method agreed at the 95% confidence level with those from a HPLC method. Finally, a procedure for simultaneous determination of aspartame and sodium cyclamate was developed, once the oxidation peak potentials of the aspartame and sodium cyclamate are 1.6 V and 1.9 V, respectively. The analytical curves were linear in the aspartame concentration range from 5.0 x 10-6 to 4.0 x 10-5 mol L-1, with detection limit of 3.5 x 10-7 mol L-1 and from 5.0 x 10-5 to 4.0 x 10-4 mol L-1, with detection limit of 4.5 x 10 -6 mol L-1 for sodium cyclamate. The simultaneous determination of these sweeteners in various dietary products was implemented with success.
Siga as redes sociais do SIBi
Contato

Repositório Institucional da UFSCar (RI UFSCar)

Av. Biblioteca Comunitária, Campus São Carlos

Rod. Washington Luís, km 235 - SP-310

São Carlos, SP, 13565-905 (16) 3351-8477

Email: repositorio@ufscar.br

Acessos ao repositorio.ufscar.br

DSpace software copyright © 2002-2026 LYRASIS

  • Acessibilidade
  • Política de Privacidade
  • Termos de Uso