Resumo
Introduction: The evaluation of the pelvic floor musculature (MAP) is important because
through this it is possible to verify possible dysfunctions of the floor musculature
pelvic floor (DMAP) that can have repercussions in urinary and fecal incontinence, prolapse of
pelvic organs and sexual dysfunction Therefore, one of the methods of evaluating the
MAP's function is through bidigital palpation using the PERFECT scheme.
Objective: To evaluate the inter and intra-examiner reproducibility of the PERFECT scheme for
evaluation of the pelvic floor musculature by means of bidigital vaginal palpation.
Materials and methods: This is a test-retest reproducibility study. Were
41 women were evaluated, with a mean age of 23.7 years old (with standard deviation
3.9). A researcher carried out the participants' anamnesis and randomization of the
order of the examiners who underwent bidigital vaginal palpation and graduation of the
MAP function through the PERFECT scheme (P = ”power”, voluntary contraction
maximum (CVM); E = "endurance", maximum sustained contraction (CSM); R = ”repetition”,
repetitions of CSM contractions; F = ”fast”, repetitions of fast contractions ”;
ECT = ”every contraction timed”, monitoring contractions). It was adopted a time of
ten-minute rest between assessments. One of the examiners repeated the assessment
7-10 days from the first meeting. The reproducibility of the data was analyzed using
of the kappa coefficient test for ordinal data, and intraclass correlation coefficient
(ICC) for numerical data. Results: Inter-examiner reproducibility was
considered moderate for the items “P” (k = 0.57), “E” (ICC = 0.53) and “F” (ICC = 0.65) and low
for item “R” (ICC = 0.27). Intra-examiner reproducibility was substantial for the
item “P” (k = 0.62), moderate for items “E” (ICC = 0.62) and “F” (ICC = 0.55) and low for item
item “R” (ICC = 0.26). Conclusion: CVM reproducibility was greater when performed
by just one researcher. However, the assessment of sustained contraction and repetitions
of fast and slow contractions shows equal reproducibility in the evaluations performed
by one researcher at two different times, or by two researchers at one
same evaluation day.
Descrição
Palavras-chave
Citação
FERNANDES, Jéssica Gabriela de Godoi. Reprodutibilidade inter e intra-examinador do esquema perfect por meio da palpação vaginal bidigital. 2020. Trabalho de Conclusão de Curso (Graduação em Fisioterapia) – Universidade Federal de São Carlos, São Carlos, 2020. Disponível em: https://repositorio.ufscar.br/handle/20.500.14289/13050.
Coleções
item.page.endorsement
item.page.review
item.page.supplemented
item.page.referenced
Licença Creative Commons
Exceto quando indicado de outra forma, a licença deste item é descrita como Attribution-NonCommercial-NoDerivs 3.0 Brazil